Z BOILER
Computer loaded through-flow type waste heat recovery steam boiler
  ECS Series
For diesel/gasoline engines
Evaporation amount : 200-1,400 kg/h
Corresponding generator : 400-3,000 kW

ECS
Main Features
  • Through intelligent AI function, a more reliable steam is supplied
  • Display function makes it possible to prevent steam stop
  • Information and communication function makes it possible to establish a highly accurate online maintenance
  • Seven items corresponding to heat management for the boiler itself are shown in the panel

Information
AI incorporated for an even more stable steam supply
A computer has been incorporated into the waste heat recovery boiler to ensure continued overall efficiency of cogeneration. A more detailed control allows highly efficient and stable waste recovery for a safe and extended useful life


New Control Functions
Operation with a high level of safety and accuracy
Steam pressure sensor
Waste gas pressure sensor
Automatic control of water concentration
  • Compared to traditional pressure switches, a more accurate control stabilizes the steam pressure.
  • Automatic compensation of the boiler data according to steam pressure has made possible a more accurate control.
  • Monitoring of waste gas pressure activates by-pass operation in case of failure.
  • AI function carries out automatic drainage at a given flow rate, keeping water concentration in the boiler at a set value. If water concentration in the boiler exceeds a set value, the sensor detects it and automatic drainage is activated, water concentration in the boiler is thoroughly monitored. Water concentration control is crucial for a high quality steam supply.

    1. AI function
      A more reliable steam supply
      Control changes are carried out under strict safety measures, at the same time that steam stop is prevented, continuous engine operation is maintained.
      1. Multiple damper control

      3. Counter flow avoidance control

      2. Multiple water level control

       

    2. Display function
      Boiler Stop Preventive Measures
      A large display shows the contents, and indicates the most effective maintenance measures to prevent steam stop.
      1. Damper failure

      5. Feed water shortage

      2. Scale deposition

      6. Blow period

      3. Pump capacity decrease

      7. Water level electrode failure

      4. Soot deposition

      8. Other 30 items such as counter-flow


    3. Information and communication function
      More effective Online Maintenance

      Signal monitor allows easy assessment of current steam pressure, exhaust gas pressure, and boiler electro-conductivity, making it possible to establish a highly accurate online maintenance.
      1. Operation condition signal

      4. Heat management signal

      2. Message/Alarm signal

      5. Parameters setting signal

      3. Failure/event signal

       


    4. Temperature control function
      Seven items corresponding to heat management for the boiler itself are shown in the panel

      In order to maintain a safe and stable operation, seven items, including steam output, blow amount are shown in the panel as operation data. A simple and easy to see and understand display has been installed. Boiler conditions can be assessed at a glance.
      1. Steam output 5. Feed water temperature

      2. Blow amount

      6. Operation time
      3. Exhaust gas temperature at inlet 7. Operation counter

      4. Exhaust gas temperature at outlet

       